This will also apply to the neoAir V2 and neoAir V2m
If you have a neoAir V3 in mode 2, time only. It can only be paired to one of the zones 1-8. It cannot be paired to hot water. If you wish to have the neoAir only controlling hot water, then the cylinder stat would need to be wired into one of the other 8 zones and then the thermostat paired to that zone.
To link a neoAir in Time Clock only to a UH8-RF V2:
On The UH8-RF V2, for the zone that you have wired the hot water or towel rail to.
- Set the horizontal zone to the number 1 position on the zone
On the neoAir V3
- Go to the power icon on the left
- Press and hold tick until you see SETUP.
- Press and hold tick until all the icons appear.
- Use the right arrow to change the number on the bottom left hand side to 3.
- Press tick.
- Take the battery case out and back in to reboot the thermostat.
- Temperature will not longer show, it will only show TIMER ON or TIMER OFF.
With the front cover on and connected to backplate of the UH8-RF V2
- Press and hold the zone number for 5 seconds and release.
- The zone light will flash.
- On the thermostat, go to the power icon on the left.
- Press and hold tick until you see SETUP.
- Press tick.
- Press the down arrow until you see P1.
- Press tick, a countdown will start.
- Zone light should go out on the UH8-RF V2.
- Press tick .
- Use the up arrow on the thermostat, select a time and press tick.
- It should then show TIMER ON and around 20 seconds later, the zone light should come on.
Only a neoAir V3 in mode 3, heating and timer mode would Hot Water be triggered on the UH8-RF V2. You would pair the neoAir V3 to the zone that you would want to control for heating
To Link a neoAir V3 to a UH8-RF, Heating and Timer mode:
- On the neoAir V3
- Go to the power icon on the left.
- Press and hold tick until you see SETUP.
- Press and hold tick until all the icons appear.
- Use the right arrow to change the number in the bottom left hand corner to 3.
- Press Tick
- Take the battery tray out and back in to reboot the neoAir V3
- You should now see both temperature and TIMER ON or TIMER OFF
With the front cover on and connected to backplate of the UH8-RF V2
- Press and hold the zone number for the heating for 5 seconds and release.
- The zone light will flash.
- On the thermostat, go to the power icon on the left.
- Press and hold tick until you see SETUP.
- Press tick.
- Press the down arrow until you see P1.
- Press tick, a countdown will start.
- Zone light should go out on the UH8-RF V2.
- Press tick.
- To test heating, turn the heating up on the thermostat and press tick so you see the flame
- Zone light should come on after around 20 seconds
- To test Timer, go to HOLD on the thermostat
- Press tick
- Select TIMER
- Press Turn
- Use the up arrow to select a time.
- Press tick, TIMER ON should show on the thermostat.
- Around 20 seconds, the Hot Water light should come on the UH8-RF V2 wiring centre