The RF Switch has Boiler CH1 and HW buttons and lights and a red power button
Factory Reset NeoAir V2/V2m/V3: (white background, no SETUP on right hand corner, neoAir V3 has buttons)
The factory Reset: On the thermostat
- Press and hold tick until you see ‘SETUP’.
- Press and hold tick with your finger while the box is over ‘SETUP’ for 10 seconds
- All icons should appear and you should see a number in the bottom left hand side.*
- Using the left and right keys select the following:
- 1 Heating
- 3 Heating and Time Clock (for example Hot water)
- Press tick
- Take the battery case out and then back in to reboot the thermostat.
To Pair to the RF Switch:
On the receiver
- Press and hold down CH1 until the light flashes
On the thermostat
- Go to the power icon on the left
- Press and hold down tick until you see SETUP and CLOCK
- While on SETUP press tick
- Press the down arrow to make small number P1
- Press tick
- CH1 light should go out on receiver
- Press tick on the thermostat.
- Turn heating up on thermostat, wait around 20 seconds, CH1 light should go out on thermostat.
Factory Reset NeoAir V1: (blue background SETUP in bottom right corner)
- Use the left and right keys to go to SETUP
- Press and hold tick while the box is over SETUP for 10 seconds
- All icons should appear and you will see 1 2 3 in bottom left corner
- Using the left and right keys select the following:
- 1 Heating
- 3 Heating and Time Clock (for example Hot water)
- Press tick
- Take the battery case out and then back in to reboot the thermostat.
To Pair to the RF Switch:
On the receiver
- Press and hold down CH1 until the light flashes
On the thermostat
- Use the left and right keys and move to SETUP on the right hand side
- While on SETUP press tick
- Press the down arrow to make small number P1
- Press tick
- CH1 light should go out on receiver
- Press tick on the thermostat.
- Turn heating up on thermostat, wait around 20 seconds, CH1 light should go out on thermostat.