When the UH8-RF is coming on every hour when a thermostat is not paired to it.
If you are no longer using a zone on a UH8-RF, you will need to deactivate the zone, otherwise that zone will enter failsafe, meaning that the redundant zone will come on for 12 minutes every hour.
When using a neoAir V2 or neoAir V3
Using a working neoStat V2 or V3
- Using the left and right buttons, move the box until it is over the power icon on the left.
- Press and hold Tick until you see SETUP and CLOCK.
- Press Tick on SETUP, then down to P2 and press Tick (make a note of the large number small number and two letters).
- On the same screen, press tick once and change the small number to match the zone that you wish to deactivate on the UH8-RF.
- After pressing tick a few times, it will go back to the original screen.
- Press and hold Tick until you see SETUP and CLOCK.
- Press Tick on SETUP, then down to P3 and press Tick.
- Use the left arrow to make the large number 00.
- Then press Tick.
Turn heating up and down, you should see the Zone light coming on the UH8-RF go off and on, this is sending a message to the wiring centre to unpair a thermostat previously connected to the UH8-RF on zone 1. This will need to be done 4 times. This will mean that the information will be transmitted on the UH8-RF to turn that zone off.
The next step is to put the thermostat back to the original settings.
Back to the thermostat
- Go to the power icon on the left using the left button
- Press and hold Tick until you see SETUP and CLOCK
- Press Tick on SETUP, then down to P2 and press Tick
- Press Tick and go to the small number, change it back to the original number, then press Tick to go back to the main screen.
- Press and hold Tick until you see SETUP and CLOCK
- Press Tick on SETUP, then down to P3 and press Tick
- Use the left arrow to make the large number 01.
- Then press Tick.
Turn the heating up and down making sure that the correct zone turns on and off on the UH8-RF
When using the neoStat V1
Using a working neoAir
- Use the right arrow to move to SETUP on the right hand side
- Press tick
- Press down arrow to go to P2 and press Tick
- Press Tick and go to the small number, change it back to the zone number you want to clear, then press Tick to go back to the main screen.
- Using the left and right keys to go to SETUP
- Press tick
- Press down arrow to go to P3
- Press tick
- Press left arrow to make large number 00.
- Press tick
Turn heating up and down, you should see the Zone light coming on the UH8-RF go off and on, this is sending a message to the wiring centre to unpair a thermostat previously connected to the UH8-RF on zone 1. This will need to be done 4 times. This will mean that the information will be transmitted on the UH8-RF to turn that zone off.
Then you need to put the neoAir back to the original settings
- Use the right arrow to move to SETUP on the right hand side
- Press tick
- Press down arrow to go to P2 and press Tick
- Press Tick and go to the small number, change it back to your original number, then press Tick to go back to the main screen.
- Using the left and right keys to go to SETUP
- Press tick
- Press down arrow to go to P3
- Press tick
- Press right arrow to make large number 01.
- Press tick
- Then test by turning heating up and ensuring that the UH8-RF zone light comes on.