Please note that this is a guide, if you have any doubt on your current setup, either contact the Support team on 01254 669090, option 2 or send an email to support@heatmiser.com, put a subject as FAO Equipment. If you can, add any pictures and information and what type of system you are controlling?
Manuals can be found here
* neoStat WIFI is for water based heating only, not electric heating. In addition if you are going to have a mixture of electric and water based heating zone or any zones that cannot be wired, you are better off using the neoHub option.
** neoStat 12v will not work with an existing Touchpad or Netmonitor which incidentally are now also discontinued. If you are looking at App control, you would need the neoHub.
*** miniHub Heating and Hot Water. Designed for one or two zone of radiators plus hot water, unable to be upgraded further. If you are looking at a larger setup like a mixture of electric and water based systems, the neoHub option would be better.
Thermostats | |||
Water Based Heating 240V Thermostats |
|||
Discontinued Model | Replacement | Additional Information | |
neoStat | neoStat V2 | A neoStat V2 can be used instead with a neoHub for App control or a neoStat WIFI * which does not use a neoHub | |
PRT Slimline Slimline V2 Slimline V3 |
|||
PRT-TS DT-TS Touch |
|||
SmartStat DT-TS WIFI PRT-TS WIFI |
neoStat WIFI does not require a neoHub. |
||
Water Based Heating 12V Thermostats | |||
Discontinued Model | Replacement | Additional Information | |
PRT-N PRT-NTS PRT-ENTS DT-N DT-NTS Slimline-N Touch-N neoStat 12v |
neoStat 12v V2 ** | neoStat 12v can work with a neoHub | |
PRT-HWN Touch-HWN |
2x neoStat 12v V2 | As we do not have one controller that does both anymore, you would need two, one in heating mode the other in timer mode, the heating stat would need to be wired from A1 and A2 from the thermostat to A1 and A2 on the wiring centre, the second stat would need to be wired form A1 and A2 from the thermostat to B1 and B2 on the wiring centre. | neoStat 12v V2 can work with a neoHub for App control |
Radio Frequency Thermostats |
|||
Discontinued Model | Replacement | Additional Information | |
Slimline RF Slimline RF V2 Touch RF |
Slimline RF V3 | Touch RF can also be replaced by the neoAir V3 | |
neoAir V3 neoAir V2 neoAir V2m Touch RF |
neoAir V3 | Slimline RF or Touch RF thermostats can also be changed to neoAir V3 |
Any version of the neoAir can work with a neoHub for App control |
PRT-W/RC1-W PRT-WTS/RC1-WTS |
Both thermostats and receiver would need to be replaced | ||
PRT-W DT-W PRT-UWTS PRTHW-W connected to UH1-W |
Both thermostats and wiring centre would need to be replaced |
||
PRT-EW/RC2-W PRTEWTS/RC2-W (Electric Radiators) |
Both thermostat and receiver would need to be replaced | ||
PRT-EW/RC2-W PRTUWTS/RC2-W (Electric Underfloor Heating) |
Radio Frequency stats no longer available for electric underfloor heating, however existing floor probe would wire into new stat. | ||
PRT-W DT-W PRT-UWTS PRTHW-W connected to UH1-W |
Both thermostats and wiring centre would need to be replaced |
||
240V Electric Based Heating |
|||
Discontinued Model | Replacement | Additional Information | |
PRT-ETS Touch-E |
A neoStat-e V2 can be used instead with a neoHub for App control |
Existing floor probes from older Heatmiser thermostats will work with the new products.
|
|
PRT-E Slimline-E Slimline-E V2 FH-01 |
Slimline-E V3 | ||
neoStat-e | neoStat-e V2 | ||
Wiring Centres | |||
Discontinued Model | Replacement | Additional Information | |
UH1 | UH8-N | Any thermostat that can connect to the UH1 will work with the UH8-N | Thermostats can be replaced with neoStat 12v V2 plus a neoHub for App control |
UH1-W | UH8-RF V2 | All thermostats will need to be replaced with either neoAir V3 or Slimline RF V3 | Slimline RF V3 cannot be used for App control, only neoAir V3 with a neoHub. |
UH2 | UH4 | Any thermostat that is connected to the UH2 will work with the UH4 | Thermostats can be replaced with neoStat V2 plus a neoHub for App control |
UH3 | UH8 | Any thermostat that is connected to the UH3 will work with the UH8 | |
UH8-RF | UH8-RF V2 | Any thermostat that connects to the UH8-RF will work with UH8-RF V2 | Any of the neoAir range can also link to a neoHub for App control, however the Slimline RF or Touch RF range cannot. |
Receivers |
|||
Discontinued Model | Replacement | Additional Information | |
RF Switch |
neoAir, Slimline RF or Touch RF will work with either receiver. (The PRT-W or PRT-WTS will not). |
||
neoHub |
|||
Discontinued Model | Replacement | Additional Information | |
neoHub |
neoHub G2 |
Any stats that can connect to a neoHub will work with the neoHub G2, however if you are unable to delete the stats off the original neoHub, then you would need to factory reset the stats before pairing to the neoHub Gen 2. (HomeKit Enabled neoHub). | |
Time Clocks |
|||
Discontinued Model | Replacement | Additional Information | |
TM1 | Slimline V4 | Can be converted to a timeclock | |
neoStat-hw | neoStat-hw V2 | neoStat-hw V2 can work with a neoHub | |
TM1-N | Can be converted to a time clock and link to a neoHub | Cannot connect to a Touchpad | |
TM4-TS | 4 Channel time clock |