This also applies to the neoAir V1, V2 and V2m
Yes you can, you would remove the front cover off the neoAir V3.
Just wire the probe wires to the two terminals to the left of where the battery tray is. It does not matter which way they go round.
To enable the probe you would do the following (neoAir V2,V2m,V3)
On the thermostat go to the power icon on the left
Press and hold until you see SETUP
Press tick once you will see 01
Press the up arrow to make the small number 06
Use the left and right keys to select the big number
- 00 will only use the internal sensor (the probe is not used)
- 01 will use the external sensor as an air sensor, the internal sensor will be disabled.
- 02 will use the external sensor as a floor probe, the internal sensor will be disabled.
- 03 will show the internal sensor temperature, however the floor probe will be active to act as a floor limiter. You can check the floor temperature by holding the left and right keys for 5 seconds.
The menu is the same on the neoAir V1, however to get to it, go to SETUP on the right hand side, press tick.
Press the up arrow to make the small number 06.