On the UH8-RF V2:
• Press and hold the pairing button on the desired channel until the output indicator LED
flashes. Pairing mode is now active on the UH8-RF V2.
If you get 4 quick flashes and LED goes out, it means you have reset the zone, try again and ensure that the LED is flashing when you let go.
If you have problems pairing, turn the power off on the UH8-RF V2 and then turn it back on again.
On the neoAir V2/V2m/V3 (White backlight no SETUP in bottom right corner)
• Use the Left arrow key to highlight the Power icon on the menu
• Press and hold TICK for 3 seconds
• SETUP is now highlighted, press once to access the setup menu
• The display will show the number 01 in the top right hand corner.
• Press the Down arrow key once, P1 is displayed in the top right corner
• Press TICK once
• The display will start counting down from 99, pairing mode is now active on the neoAir
On the neoAir V1 (Blue backlight, SETUP in bottom right corner)
• Use the left/right keys to move to SETUP
• Press tick
• The display will show the number 01 in the top right hand corner.
• Press the Down arrow key once, P1 is displayed in the top right corner
• Press TICK once
• The display will start counting down from 99, pairing mode is now active on the neoAir
On the UH8-RF V2
The zone LED should stop flashing, indicating that pairing is complete.
Test the zone by turning the heating up on the thermostat so you get the flame icon. If paired correctly, the UH8-RF V2 should come on around 20 seconds later.
The aerial on the UH8-RF should always point upwards overwise it will weaken the signal. If you are unable to do this with the smaller aerial, use the aerial with the longer cable.