On the UH8-RF, take note of the numbers set on the rotary switches. (UH8-RF ID Numbers 01-99)
Each UH8-RF on the system needs to have a different ID number.
Set your first UH8-RF to 01
At the thermostat
- Use the Left/Right arrow keys to scroll to SETUP and press TICK once
- The display will now show 01 in the Top right hand corner
- Press DOWN arrow twice so that you see P2 on the display
- Press TICK once
- Use the Left/Right arrow keys to set the large digits to the board address of the UH8-RF (This is the number set on the UH8-RF Rotary switch)
- Press TICK
- You should now see the small digits in the top right corner flash
- Use the Up/Down keys to select the zone this thermostat should be paired to
- Press TICK
- Use the Up/Down keys to select the Zone Type (Radiators = RA / Underfloor Heating = UF)
- Press TICK to Finish